Violation Detail
Standard Cited: 19100217 C03 III F Mechanical power presses.
Inspection Nr: 1096950.015
Citation: 01005
Citation Type: Serious
Abatement Date: 02/13/2017 2
Initial Penalty: $6,300.00
Current Penalty: $4,410.00
Issuance Date: 12/22/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 10
Report ID: 0524700
Contest Date: 01/15/2016
Final Order: 01/20/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/20/2017 | $4,410.00 | 02/13/2017 | Serious | |
Penalty | C: Contested | 01/20/2016 | $6,300.00 | 01/19/2016 | Serious | |
Penalty | Z: Issued | 12/22/2015 | $6,300.00 | 01/19/2016 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.217(c)(3)(iii)(f): Mechanical power press(es) using presence sensing point of operation devices were not provided with guards to protect all areas of entry to the point of operation not protected by the presence sensing device(s): a) On or about October 6, 2015, the employer did not ensure that the Minster 7 (#4045) press was guarded in the area where the light curtain did not cover. Employees were exposed to amputation injuries from the point of operation due to the lack of guarding.