Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1067666.015
Citation: 01004
Citation Type: Serious
Abatement Date: 08/25/2015 2
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 07/30/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 08/20/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/20/2015 | $4,900.00 | 08/25/2015 | Serious | |
Penalty | Z: Issued | 07/30/2015 | $7,000.00 | 08/25/2015 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about May 27, 2015, the employer did not ensure employees isolated the electrical, pneumatic, and mechanical energy sources of a Niagara 50 ton, part revolution mechanical power press, Serial No. 30223, known as the Mini Line #4, during die changes, material changes, and the changing of punches inside the point of operation.