Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1053446.015
Citation: 02001A
Citation Type: Willful
Abatement Date: 11/16/2015 2
Initial Penalty: $70,000.00
Current Penalty: $56,000.00
Issuance Date: 09/28/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/22/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/22/2015 | $56,000.00 | 11/16/2015 | Willful | |
Penalty | Z: Issued | 09/28/2015 | $70,000.00 | 10/02/2015 | Willful |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) On April 7, 2015, the employer did not ensure hazardous energy control procedures (lockout/tagout) were utilized on the #517 Giblet/Liver Chiller Machine, located in the first processing department, during cleaning and sanitization of the equipment. Energy sources include, but are not limited to: electrical and hydraulic.