Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1044716.015
Citation: 01009
Citation Type: Serious
Abatement Date: 10/31/2015 2
Initial Penalty: $2,800.00
Current Penalty: $2,200.00
Issuance Date: 08/28/2015
Nr Instances: 4
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 09/18/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/18/2015 | $2,200.00 | 10/31/2015 | Serious | |
Penalty | Z: Issued | 08/28/2015 | $2,800.00 | 09/08/2015 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) of this section: (a) Sawmill, Front (west end) - During the period March 6, 2015 through March 18, 2015 belts and pulleys on Chipper Hogg were not guarded. (b) Sawmill, Back (east end) - During the period March 6, 2015 through March 18, 2015 belts and pulleys on Chipper Hogg were not guarded. (c) Sawmill - During the period March 6, 2015 through March 18, 2015 belt and pulleys at slip table were not guarded. (d) Sawmill - During the period March 6, 2015 through March 18, 2015 belt and pulleys near head rig were not guarded.