Violation Detail
Standard Cited: 19100253 B04 III Oxygen-fuel gas welding and cutting.
Inspection Nr: 1040829.015
Citation: 02001A
Citation Type: Serious
Abatement Date: 05/16/2019 2
Initial Penalty: $5,500.00
Current Penalty: $9,625.00
Issuance Date: 08/13/2015
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0522500
Contest Date: 08/19/2015
Final Order: 03/21/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/21/2019 | $9,625.00 | 05/16/2019 | Serious | |
Penalty | F: Formal Settlement | 03/21/2019 | $9,625.00 | 05/16/2019 | Serious | |
Penalty | F: Formal Settlement | 03/21/2019 | $9,625.00 | 05/16/2019 | Serious | |
Penalty | C: Contested | 08/21/2015 | $5,500.00 | 08/25/2015 | Serious | |
Penalty | C: Contested | 08/21/2015 | $4,400.00 | 08/25/2015 | Serious | |
Penalty | C: Contested | 08/21/2015 | $3,300.00 | 08/28/2015 | Serious | |
Penalty | Z: Issued | 08/13/2015 | $3,300.00 | 08/28/2015 | Serious | |
Penalty | Z: Issued | 08/13/2015 | $5,500.00 | 08/25/2015 | Serious | |
Penalty | Z: Issued | 08/13/2015 | $4,400.00 | 08/25/2015 | Serious |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: Improper storage of liquid and gaseous chemicals; storage of acids and bases together; unattended running forklift; absence of training on safe handling of corrosive chemicals; inoperable fire extinguisher. 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least five feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Improper storage of liquid and gaseous chemicals; storage of acids and bases together; unattended running forklift; absence of training on safe handling of corrosive chemicals; inoperable fire extinguisher. 29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means shall be fully lowered, controls shall be neutralized, power shall be shut off, and brakes set. Wheels shall be blocked if the truck is parked on an incline: Improper storage of liquid and gaseous chemicals; storage of acids and bases together; unattended running forklift; absence of training on safe handling of corrosive chemicals; inoperable fire extinguisher.