Violation Detail
Standard Cited: 19100253 E01 Oxygen-fuel gas welding and cutting.
Inspection Nr: 1040362.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 04/21/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/15/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0830600
Contest Date:
Final Order: 05/01/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/01/2015 | $0.00 | 04/21/2015 | Serious | |
Penalty | Z: Issued | 04/15/2015 | $0.00 | 04/21/2015 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer: a) On or about February 12, 2015 and at times prior, employees were exposed to serious injuries from welding operations. The gauge covers were missing and indicator needles were not working on the oxygen and acetylene cylinders which were used by the employees during welding operations.