Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1021286.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 05/19/2015
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/02/2015
Nr Instances: 4
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 04/27/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/27/2015 | $0.00 | 05/19/2015 | Serious | |
Penalty | Z: Issued | 04/02/2015 | $0.00 | 05/19/2015 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard were being followed: Inside of the Production Area, periodic audits of the specific lockout/tagout procedures were not performed for the following machines: a/ Hydraulic Press Brake. b/ Standard Press Brake BR 12. c/ Mechanical Shear. d/ Hydraulic Shear.