Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1010863.015
Citation: 01006B
Citation Type: Serious
Abatement Date: 06/03/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/07/2015
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0418400
Contest Date:
Final Order: 06/09/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/09/2015 | $0.00 | 06/03/2015 | Serious | |
Penalty | Z: Issued | 05/07/2015 | $0.00 | 06/03/2015 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) At the recycling facility in Unadilla, GA: On or about November 12, 2014, and at times prior thereto, the employer exposed employees to fire hazards in the maintenance room, in that an oxygen and acetylene cylinder were not stored securely in an assigned storage space, subject to being knocked over or damaged as employees walked by and worked around the cylinders.