Violation Detail
Standard Cited: 19100213 S06 Woodworking machinery requirements.
Inspection Nr: 1010323.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/21/2015
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC): C
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 06/18/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/18/2015 | $0.00 | Serious | ||
Penalty | Z: Issued | 05/21/2015 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards: A. Main Room, Front of Shop: On, or about, November 25, 2014, dust had accumulated in the 208 volt on/off control box located on the Powermatic table saw. B. Main Room, Front of Shop: On, or about, November 25, 2014, dust has accumulated in the on/off switch box enclosure for the Max drum sander located near the doorway to the back shop.