Violation Detail
Standard Cited: 19260405 G02 IV Wiring methods, components, and equipment for general use.
Inspection Nr: 1004853.015
Citation: 01006A
Citation Type: Serious
Abatement Date: 06/02/2015 2
Initial Penalty: $7,000.00
Current Penalty: $5,400.00
Issuance Date: 04/15/2015
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0522000
Contest Date: 05/20/2015
Final Order: 02/05/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/05/2016 | $5,400.00 | 06/02/2015 | Serious | |
Penalty | C: Contested | 05/20/2015 | $7,000.00 | 06/02/2015 | Serious | |
Penalty | Z: Issued | 04/15/2015 | $7,000.00 | 06/02/2015 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: -On or about October 24, 2014 and prior to that time located at the paint mixing area there was a paint mixing drill which had been used connected to electrical service by an extension cord which at the drill hand grip had the primary insulation pulled away from the strain relief device exposing the secondary insulated conductors.