Powered by GoogleTranslate

Violation Detail

Standard Cited: 19030019 D01 Abatement verification.

Inspection Nr: 1379772.015

Citation: 03001

Citation Type: Other

Abatement Status: Abatement Completed

Initial Penalty: $438.00

Current Penalty: $438.00

Issuance Date: 05/20/2021

Nr Instances: 12

Nr Exposed: 14

Abatement Date: 06/24/2021

Gravity:

Report ID: 0522300

Contest Date:

Final Order: 06/21/2021

Related Event Code (REC): C

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty Z: Issued 05/20/2021 $438.00 06/24/2021 Other  

Text For Citation: 03 Item/Group: 001 Hazard:

29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. Project Light Inc. failed to provide documentation demonstrating the abatement methods and completion of each of the cited items described below: Citation 1 Item 1 - The warehouse floor along the north side of the building where the roof as leaking was not maintained in a clean and dry condition. Citation 1 Item 2 - Material damaged by water damage near the loading dock were not stored so that the material was stable and secure against sliding and collapse. Citation 1 Item 3 - Forklift operator training and certification. Citation 1 Item 4/a - Develop and implement a written hazard communication program. Citation 1 Item 4/b - Ensure secondary containers containing chemicals are labeled with the identity of the chemicals and hazards. Citation 1 Item 4/c - Maintain safety data sheets and ensure that they are readily accessible to employees. Citation 1 Item 4/d - Train employees on the hazardous chemicals in the workplace. Citation 2 Item 1 - Visually inspect fire extinguishers at least monthly. Citation 2 Item 2 - Train employees on the emergency action plan in case of fire. Citation 2 Item 3/a - The Dixie model HHMPS-10 Work Platform forklift attachment did not have written approval by the forklift manufacturer. Citation 2 Item 3/b - The Yale sit-down forklift was not equipped with weight capacity identification of the truck and the work platform attachment. Citation 2 Item 4 - Relocatable power taps and electrical junction boxes located at the assembly station were not installed in accordance to the manufacturer's listing and labeling.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.