Violation Detail
Standard Cited: 19260403 B01 General requirements.
Inspection Nr: 1470733.015
Citation: 02001
Citation Type: Other
Abatement Date: 04/30/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/20/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity:
Report ID: 0418200
Contest Date:
Final Order: 05/18/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 04/20/2020 | $0.00 | 04/30/2020 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) New residential construction located on Lot #347, West side of structure at cut bench: On or about 03/19/2020, and at times prior, the employer failed to inspect all electrical cords and electrical equipment prior to start of shift, in that electrical cords for the Makita circular saw had a damaged strain relief and an orange 50-ft. extension cord had a torn and frayed outer casing and were not repaired or removed from service.