Violation Detail
Standard Cited: 19261416 B
Inspection Nr: 979943.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/22/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/01/2014
Gravity: 5
Report ID: 0215800
Contest Date: 10/27/2014
Final Order: 03/16/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/16/2015 | $0.00 | 08/01/2014 | Serious | |
Penalty | C: Contested | 12/15/2014 | $0.00 | 08/01/2014 | Serious | |
Penalty | Z: Issued | 07/22/2014 | $0.00 | 08/01/2014 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1926.1416(b): Operations must not begin unless the operational aids are in proper working order, except where an operational aid is being repaired the employer uses the specified temporary alternative measures. The time periods permitted for repairing defective operational aids are specified in paragraphs (d) and (e) of this section: On or about 6/3/2014, At the job site: A Grove TMS875C Hydraulic Truck Crane was in use without its computer being calibrated. There was no boom length indicator or boom angle indicator in place other than the computer. Abatement certification is required for this item.