Violation Detail
Standard Cited: 19100179 G01 V Overhead and gantry cranes.
Inspection Nr: 1264710.015
Citation: 01004
Citation Type: Serious
Abatement Date: 03/05/2018 2
Initial Penalty: $6,047.00
Current Penalty: $3,023.50
Issuance Date: 01/26/2018
Nr Instances: 2
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 02/07/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/07/2018 | $3,023.50 | 03/05/2018 | Serious | |
Penalty | Z: Issued | 01/26/2018 | $6,047.00 | 03/05/2018 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: On or about 9/20/2017, The JAYGO HOIST pendant for mixer #10 only had one label on the pendant buttons and the JAYGO HOIST pendant for mixer #11 did not have any pendant buttons labeled which could have led to a crushing injury if the wrong button was pushed.