Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1417789.015
Citation: 01003
Citation Type: Serious
Abatement Status:
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 10/16/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/24/2019
Gravity: 10
Report ID: 0418600
Contest Date: 11/08/2019
Final Order: 08/30/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 08/30/2021 | $0.00 | 10/24/2019 | Serious | |
| Penalty | C: Contested | 11/15/2019 | $9,282.00 | 10/24/2019 | Serious | |
| Penalty | Z: Issued | 10/16/2019 | $9,282.00 | 10/24/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) LACOM MPBL CV 1800 laminator; On or about July 24, 2019 and times prior, the employer exposed employees to the hazards associated with getting caught-in the feed rolls during threading operations of the lower rollers due to the 1800 laminator not being locked out to control the energy sources present such as electric and pneumatic.