Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1222136.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2017
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 12/07/2017
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 10/05/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/05/2017 | $0.00 | 12/07/2017 | Serious | |
Penalty | Z: Issued | 09/06/2017 | $0.00 | 12/07/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. a. At the establishment press area. Lockout procedures for equipment such as, but not limited to, the Gammerler STC-70 Stacker, had no detailed procedures for the placement removal and/or transfer for lockout and/or tagout devices, on or about, 03/21/2017.