Violation Detail
Standard Cited: 19260451 B05 II General requirements.
Inspection Nr: 1412652.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,842.00
Current Penalty: $1,750.00
Issuance Date: 08/07/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 08/16/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/16/2019 | $1,750.00 | Serious | ||
Penalty | Z: Issued | 08/07/2019 | $2,842.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) On or about 06/27/19, on a roof sheeting jobsite, at a house at 716 Lafayette Ave., Buffalo, NY: A Ladder Jack Scaffold was erected on the left side of the house. Two employees were standing on the aluminum pik of that scaffold while installing roof sheeting. The pik was approx. 20 ft. long, and extended over the front support bracket by approx. 5 feet. NO ABATEMENT CERTIFICATION REQUIRED