Inspection Detail
Inspection: 311162226 - Timken Co.
Inspection Information - Office: Cleveland Area Office
Site Address:
Timken Co.
2401 Gambrinus Avenue, S.W.
Canton, OH 44706
Mailing Address:
1835 Dueber Avenue S.W., Canton, OH 44706
Union Status: Union
SIC:3312
NAICS: 331111/Iron and Steel Mills
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/03/2007
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/01/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 206264905 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $7,500 | $0 | $0 | $0 | $0 | $7,500 |
| Current Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100023 C03 | 12/07/2007 | 02/01/2008 | $3,000 | $5,000 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100176 E | 12/07/2007 | 12/25/2007 | $2,000 | $2,500 | $0 | I - Informal Settlement |
Translate