Inspection Detail
Inspection: 309619336 - Pyrotechnic Specialties, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Pyrotechnic Specialties, Inc.
1661 Juniper Creek Road
Byron, GA 31008
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2892
NAICS: 325920/Explosives Manufacturing
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/30/2006
Emphasis: N:Psmpqv, N:Sstarg06
Case Closed: 09/14/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 201290038 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 7 | 7 | ||||
| Current Violations | 7 | 7 | ||||
| Initial Penalty | $14,000 | $0 | $0 | $0 | $0 | $14,000 |
| Current Penalty | $14,000 | $0 | $0 | $0 | $0 | $14,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100119 C01 | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - | ||
| 2. | 01002A | Serious | 19100119 D03 IC | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - | ||
| 3. | 01002B | Serious | 19100119 D03 IF | 01/18/2007 | 03/07/2007 | $0 | $0 | $0 | - | ||
| 4. | 01003 | Serious | 19100119 E02 | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - | ||
| 5. | 01004A | Serious | 19100119 F04 | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - | ||
| 6. | 01004B | Serious | 19100119 J02 | 01/18/2007 | 03/07/2007 | $0 | $0 | $0 | - | ||
| 7. | 01005 | Serious | 19100119 L01 | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - | ||
| 8. | 01006 | Serious | 19100119 O01 | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - | ||
| 9. | 01007 | Serious | 19100305 G01 IIIA | 01/18/2007 | 03/07/2007 | $2,000 | $2,000 | $0 | - |