Inspection Detail
Inspection: 309200459 - Nexans Energy Usa Inc.
|
Inspection Information - Office: Albany | ||||
Nr: 309200459 | Report ID: 0213100 | Open Date: 08/09/2005 | ||
Nexans Energy Usa Inc. | ||||
25 Oakland Ave Chester, NY 10918 | Union Status: Union | |||
SIC: 3357/Drawing and Insulating of Nonferrous Wire | ||||
NAICS: 331422/Copper Wire (except Mechanical) Drawing | ||||
Inspection Type: | Planned | |||
Scope: | Complete | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 08/09/2005 | |
Emphasis: | N:Sstarg04 | Close Case: | 11/08/2005 |
Serious | Willful | Repeat | Other | Unclass | Total | |
---|---|---|---|---|---|---|
Initial Violations | 6 | 1 | 7 | |||
Current Violations | 6 | 1 | 7 | |||
Initial Penalty | $7,875 | $0 | $0 | $0 | $0 | $7,875 |
Current Penalty | $7,875 | $0 | $0 | $0 | $0 | $7,875 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100036 D01 | 09/23/2005 | 09/28/2005 | $1,125 | $1,125 | $0 | - | ||
2. | 01002 | Serious | 19100037 A03 | 09/23/2005 | 10/01/2005 | $1,125 | $1,125 | $0 | - | ||
3. | 01003 | Serious | 19100037 B04 | 09/23/2005 | 10/16/2005 | $1,125 | $1,125 | $0 | - | ||
4. | 01004 | Serious | 19100253 B04 I | 09/23/2005 | 10/01/2005 | $1,500 | $1,500 | $0 | - | ||
5. | 01005 | Serious | 19100303 G02 II | 09/23/2005 | 10/16/2005 | $1,500 | $1,500 | $0 | - | ||
6. | 01006 | Serious | 19100305 B01 | 09/23/2005 | 10/01/2005 | $1,500 | $1,500 | $0 | - | ||
7. | 02001 | Other | 19100036 E01 | 09/23/2005 | 10/26/2005 | $0 | $0 | $0 | - |