Inspection Detail
Inspection: 309022374 - Allied Tube & Conduit
Inspection Information - Office: Chicago South Area Office
Site Address:
Allied Tube & Conduit
16100 S. Lathrop Avenue
Harvey, IL 60426
Mailing Address:
, , 00000
Union Status: Union
SIC:3317
NAICS: 331210/Iron and Steel Pipe and Tube Manufacturing from Purchased Steel
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/22/2005
Emphasis:
Case Closed: 11/30/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 204687388 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | 4 | |||
| Current Violations | 1 | 3 | 4 | |||
| Initial Penalty | $3,775 | $0 | $0 | $1,000 | $0 | $4,775 |
| Current Penalty | $1,275 | $0 | $0 | $0 | $0 | $1,275 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100219 D01 | 10/26/2005 | 06/01/2005 | $1,275 | $1,275 | $0 | - | ||
| 2. | 01001B | Serious | 19100219 E03 I | 10/26/2005 | 06/01/2005 | $0 | $0 | $0 | - | ||
| 3. | 01002 | Other | 19100303 B01 | 10/26/2005 | 10/31/2005 | $0 | $2,500 | $0 | I - Informal Settlement | ||
| 4. | 02001 | Other | 19101200 F05 I | 10/26/2005 | 10/31/2005 | $0 | $1,000 | $0 | I - Informal Settlement | ||
| 5. | 02002 | Other | 19101200 F05 II | 10/26/2005 | 10/31/2005 | $0 | $0 | $0 | - |