Inspection Detail
Inspection: 308816511 - Michigan Wire Processing Inc Plants 1 & 2
Inspection Information - Office: Miosha General Industry Safety & Health Division
Site Address:
Michigan Wire Processing Inc Plants 1 & 2
138 S Water St
Lowell, MI 49331
Mailing Address:
Po Box 70, Lowell, MI 49331
Union Status: Union
SIC:3398
NAICS: 332811/Metal Heat Treating
Inspection Type: Planned
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/09/2008
Planning Guide: Safety-Manufacturing
Emphasis: S:Amputations, S:Enf Targeted, S:Noise, S:Primary Metal
Case Closed: 10/01/2008
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 3 | 7 | |||
| Current Violations | 4 | 3 | 7 | |||
| Initial Penalty | $1,800 | $0 | $0 | $0 | $0 | $1,800 |
| Current Penalty | $900 | $0 | $0 | $0 | $0 | $900 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 4081073101 | 09/12/2008 | 09/12/2008 | $225 | $450 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 4081217601 | 09/12/2008 | 09/12/2008 | $225 | $450 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 4081331201 | 09/12/2008 | 09/12/2008 | $225 | $450 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19100303 G02 I | 09/12/2008 | 09/12/2008 | $225 | $450 | $0 | I - Informal Settlement | ||
| 5. | 02001 | Other | 4081541602 | 09/12/2008 | 09/12/2008 | $0 | $0 | $0 | - | ||
| 6. | 02002 | Other | 19100303 B01 II | 09/12/2008 | 09/12/2008 | $0 | $0 | $0 | - | ||
| 7. | 02003 | Other | 19100305 G01 IV | 09/12/2008 | 09/12/2008 | $0 | $0 | $0 | - |