Powered by GoogleTranslate

Inspection Detail

Inspection: 305647000 - Precious Metals Inc

Inspection Information - Office: Pr-E-Caguas 0257220

 

Inspection Nr: 305647000
Report ID: 0257220
Date Opened: 11/13/2002

Site Address:
Precious Metals Inc
Calle Lincoln 250
Cayey, PR 00737

Mailing Address:
Po Box 372917, Cayey, PR 00737

Union Status: NonUnion

SIC:3471

NAICS: 332813/ Electroplating, Plating, Polishing, Anodizing, and Coloring


Inspection Type: Planned

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/02/2003

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 05/27/2003


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $1,650 $0 $0 $0 $0 $1,650
Current Penalty $990 $0 $0 $0 $0 $990
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100134 E01 05/07/2003 06/03/2003 $360 $600 $0 I - Informal Settlement  
2. 01002 Serious 19100151 C 05/07/2003 05/12/2003 $630 $1,050 $0 I - Informal Settlement  
3. 02001A Other 19100134 C02 I 05/07/2003 06/03/2003 $0 $0 $0 -  
4. 02001B Other 19100134 C02 II 05/07/2003 06/03/2003 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.