Powered by GoogleTranslate

Inspection Detail

Inspection: 303521397 - Bloques Adjuntas

Inspection Information - Office: Pr-E-Ponce 0257250

 

Inspection Nr: 303521397
Report ID: 0257250
Date Opened: 04/26/2001

Site Address:
Bloques Adjuntas
Carr 10 Km 35.8 Bo Garzas
Adjuntas, PR 00601

Mailing Address:
Box 646, Adjuntas, PR 00601

Union Status: NonUnion

SIC:3271

NAICS: 0 


Inspection Type: Planned

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/29/2001

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/03/2004


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $1,350 $0 $0 $150 $0 $1,500
Current Penalty $1,350 $0 $0 $150 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100023 C01 05/07/2001 05/15/2001 $450 $450 $0 -  
2. 01002 Serious 19100178 L01 I 05/07/2001 05/25/2001 $450 $450 $0 -  
3. 01003 Serious 19100303 G02 I 05/07/2001 05/13/2001 $450 $450 $0 -  
4. 02001 Other SPECRULE 1VI 11 05/07/2001 05/15/2001 $150 $150 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close