Powered by GoogleTranslate

Inspection Detail

Inspection: 300419561 - Atlantic Pipe Corporation

Inspection Information - Office: Pr-E-Ponce 0257250

 

Inspection Nr: 300419561
Report ID: 0257250
Date Opened: 07/17/1997

Site Address:
Atlantic Pipe Corporation
Car 14 Km 11.2 Bo Jacaguas
Juana Diaz, PR 00795

Mailing Address:
G P O Box 366259, San Juan, PR 00936

Union Status: Union

SIC:3272

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/09/1997

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 10/16/1997


Related Activity
Type Activity Nr Safety Health
Referral 902176783 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $450 $0 $0 $0 $0 $450
Current Penalty $270 $0 $0 $0 $0 $270
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100253 B04 III 09/18/1997 09/22/1997 $270 $450 $0 I - Informal Settlement  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.