Inspection Detail
Inspection: 214627473 - Stromag Inc
Inspection Information - Office: Cincinnati Area Office
Site Address:
Stromag Inc
95 Compark Road
Centerville, OH 45459
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3599
NAICS: 0
Inspection Type: FollowUp
Scope: Complete
Advanced Notice:
Ownership:
Safety/Health: Safety
Close Conference: 08/07/1975
Emphasis:
Case Closed: 06/30/1976
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Inspection | 214632747 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 7 | 11 | |||
| Current Violations | 4 | 7 | 11 | |||
| Initial Penalty | $0 | $0 | $200 | $0 | $0 | $200 |
| Current Penalty | $0 | $0 | $200 | $0 | $0 | $200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100242 B | 08/13/1975 | 08/13/1975 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 19100212 B | 08/13/1975 | 08/13/1975 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Other | 19100023 C01 | 08/13/1975 | 09/25/1975 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Other | 19100309 A 025045 | 08/13/1975 | 08/13/1975 | $0 | $0 | $0 | - | ||
| 5. | 01005 | Other | 19100309 A 011017 | 08/13/1975 | 08/13/1975 | $0 | $0 | $0 | - | ||
| 6. | 01006 | Other | 19100219 E03 I | 08/13/1975 | 09/25/1975 | $0 | $0 | $0 | - | ||
| 7. | 01007 | Other | 19100219 D01 | 08/13/1975 | 09/25/1975 | $0 | $0 | $0 | - | ||
| 8. | 02001 | Repeat | 19100215 B09 | 08/13/1975 | 08/13/1975 | $50 | $50 | $0 | - | ||
| 9. | 03001 | Repeat | 19100157 D02 I | 08/13/1975 | 08/13/1975 | $50 | $50 | $0 | - | ||
| 10. | 04001 | Repeat | 19100212 A01 | 08/13/1975 | 09/25/1975 | $50 | $50 | $0 | - | ||
| 11. | 05001 | Repeat | 19100219 E01 I | 08/13/1975 | 09/25/1975 | $50 | $50 | $0 | - |