Inspection Detail
Inspection: 17923087 - Collyer Insulated Wire
Inspection Information - Office: Providence Area Office
Site Address:
Collyer Insulated Wire
100 Higginson Avenue
Lincoln, RI 02865
Mailing Address:
, , 00000
Union Status: Union
SIC:3357
NAICS: 0
Inspection Type: Complaint
Scope: Records
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/07/1988
Emphasis:
Case Closed: 03/02/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 72142276 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $0 | $612,000 | $0 | $0 | $0 | $612,000 |
| Current Penalty | $0 | $225,000 | $0 | $0 | $0 | $225,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Willful | 19040002 A | 04/13/1988 | 09/08/1989 | $225,000 | $612,000 | $0 | 05/03/1988 | R - Review Commission | |
| 2. | 02001 | Other | 19040004 | 04/13/1988 | 05/04/1988 | $0 | $0 | $0 | 05/03/1988 | - |
Translate