Powered by GoogleTranslate

Inspection Detail

Inspection: 110689155 - Uniflow Corp Plants #1 #3 #4

Inspection Information - Office: Miosha General Industry Safety & Health Division

 

Inspection Nr: 110689155
Report ID: 0552652
Date Opened: 05/20/1993

Site Address:
Uniflow Corp Plants #1 #3 #4
26600 Heyn Dr 46035 Grand River 46039 Grand River
Novi, MI 48374

Mailing Address:
, , 00000

Union Status: Union

SIC:3356

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/20/1993

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/21/1993


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $2,000 $0 $0 $0 $0 $2,000
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 40810011 A 06/11/1993 07/05/1993 $0 $0 $0 -  
2. 01002 Serious 40810011 C 06/11/1993 07/05/1993 $1,000 $1,000 $0 -  
3. 01003 Serious 4081246201 06/11/1993 07/05/1993 $1,000 $1,000 $0 -  
4. 02001 Other 19100169 B02 06/11/1993 07/19/1993 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.