Inspection: 106207285 - Aci Insulation, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 106207285
Report ID: 0420600
Date Opened: 10/12/1990

Site Address:
Aci Insulation, Inc.
8298 North Wickham Rd.
Melbourne, FL 32940

Mailing Address:
631 Triumph Court #3, Orlando, FL 32805

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/15/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/15/1991


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $480 $0 $0 $0 $0 $480
Current Penalty $480 $0 $0 $0 $0 $480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260059 E01 11/06/1990 12/11/1990 $160 $160 $0 -  
2. 01002 Serious 19260059 G01 11/06/1990 11/09/1990 $160 $160 $0 -  
3. 01003 Serious 19260059 H 11/06/1990 12/11/1990 $160 $160 $0 -  
4. 02001 Other 19260020 B01 11/06/1990 12/11/1990 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.