Powered by GoogleTranslate

Inspection Detail

Inspection: 101608107 - Bryan Custom Plastics

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 101608107
Report ID: 0524700
Date Opened: 02/12/1986

Site Address:
Bryan Custom Plastics
918 S. Union St.
Bryan, OH 43506

Mailing Address:
P.O.Box 568, Bryan, OH 43506

Union Status: Union

SIC:3089

NAICS: 0 


Inspection Type: Complaint

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/14/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/02/1986


Related Activity
Type Activity Nr Safety Health
Complaint 70947692 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 3 5
Current Violations 1 1 3 5
Initial Penalty $420 $0 $170 $0 $0 $590
Current Penalty $420 $0 $170 $0 $0 $590
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100024 B 03/19/1986 05/24/1986 $420 $420 $0 -  
2. 02001 Repeat 19100215 A04 03/19/1986 03/22/1986 $170 $170 $0 -  
3. 03001 Other 19100037 Q01 03/19/1986 05/24/1986 $0 $0 $0 -  
4. 03002 Other 19100106 E02 IVB 03/19/1986 05/24/1986 $0 $0 $0 -  
5. 03003 Other 19100215 B09 03/19/1986 03/22/1986 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close