Accident Summary Nr: 994038 - Two employees injured in fall when scaffold collapses

Accident Summary Nr: 994038 -- Report ID: 0452110 -- Event Date: 03/11/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12459610703/11/199417610L G & N Contractors

Abstract: On March 11, 1994, at approximately 11:20 a.m., a carpenter's bracket scaffold collapsed while Employees #1 and #2 were standing on the scaffold platform to nail down a corner of a roof frame on a single family, private home under construction prior to attaching tarpaper and shingles. The scaffold was 17 feet 2 inches above the ground in the area where Employees #1 and #2 fell. The scaffold platform consisted of a single aluminum walkboard 16 feet long and 12 inches wide with a rated load capacity of 250 pounds. No guardrails or toe boards were utilized and the platform was accessed from the roof. The only materials on the scaffold platform with them were hammers and their nail pouches. Employee #1 sustained a crushed artery in his right leg, and Employee #2 dislocated his left elbow. The scaffold fell when the metal bracket pulled free from the side of the structure. The brackets had been attached by Employee #1 using seven #16, double-headed nails. The bracket which fell had been attached five days previously. The nearest bracket was 11 feet 3 inches away.

Keywords: PLATFORM, ROOF, CONSTRUCTION, SCAFFOLD COLLAPSE, CRUSHED, DISLOCATED, FALL, FALL PROTECTION, ARTERY, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124596107 Hospitalized injury Puncture Roofers
2 124596107 Non Hospitalized injury Dislocation Roofers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close