Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 889972 - Three employees injured as gas heat exchanger ruptures

Accident Summary Nr: 889972 -- Report ID: 0352430 -- Event Date: 09/28/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10447790610/04/199034430Industrial Services Contractors Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10447805210/01/199033120Bethlehem Steel Corporation

Abstract: At 2:00 p.m. on September 28, 1990, Employees #1, #2, and #3 had been working from a platform at the L blast furnace facility at the Bethlehem Steel Corporation installing pump sealant around the tuyere coolers. The #2 stove gas heat exchanger ruptured at a split weld seam and released a blast of pressure from the stove. Debris flew into the eyes of the three employees. They jumped from the platform and suffered bruises to their hips, kidneys, ribs, and stomachs, pulled groins, and debris in their throats. The employer provided on the job training for the employees.

Keywords: HEAT EXCHANGER, ELEVATED WORK PLAT, CONTUSION, EYE, INSTALLING, BROKEN WELD, RUPTURE, STRUCK BY, FLYING OBJECT, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104477906 Hospitalized injury Foreign Body Ineye Plumber, pipefitter and steamfiter apprentices
2 104477906 Hospitalized injury Foreign Body Ineye Plumber, pipefitter and steamfiter apprentices
3 104477906 Hospitalized injury Bruise/Contus/Abras Plumber, pipefitter and steamfiter apprentices
4 104478052 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close