Accident Report Detail
Accident Summary Nr: 887836 - Employee's fingertips amputated in press brake
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 104365416 | 02/08/1989 | 3446 | 0 | Bettinger West Inc. |
Abstract: Employee #1 was forming metal parts using a Toledo Machine and Tool Company full revolution press brake (plate motor No. 526084-2) operated by a foot treadle. Three fingertips of his left hand became caught between the die sections. His index finger was amputated to halfway down the nail; his middle finger to three-quarters down the nail; and his ring finger to the first joint. There were no witnesses. Employee #1 had on-the-job training and had previously operated this machine. There was no point-of-operation guard on the machine.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 104365416 | Hospitalized injury | Amputation | Punching and stamping press machine operators |
Translate