Accident: 878686 - Electric Shock - Ground Fault In Toaster Oven

Accident: 878686 -- Report ID: 0352430 -- Event Date: 08/17/1990
InspectionOpen DateSICEstablishment Name
10447536308/17/19903312Bethlehem Steel Corporation
An employee came into a lunchroom that was also used as a cool down area. The employee sat down next to a floor model air conditioner. A Hamilton Beach toaster oven sat on top of the air conditioner. The employee's right leg was touching the side of the air conditioner. He placed his right arm on top of the toaster oven and was electrocuted. Inspection of the equipment revealed that the air conditioner was grounded but that the toaster oven was not. Additionally, the toaster oven was not provided with a polarized plug, and its heating element was broken and in contact with the oven's metal frame.
Keywords: toaster, electrical, e gi vii, electrocuted, ground fault
Employee # Inspection Age Sex Degree Nature Occupation
1 104475363 Fatality Electric Shock Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.