Accident: 873570 - Employee Killed When Struck By Falling Crane Boom

Accident: 873570 -- Report ID: 0521400 -- Event Date: 09/21/1998
InspectionOpen DateSICEstablishment Name
30059067609/21/19981611Herlihy Mid-Continent
A crane was travelling with a suspended, approximately 16,000 lb load on an uneven route. The crane tipped over, causing the boom and the load to swing around the left side of the crane. The boom came down with the load, striking and killing Employee #1.
Keywords: uneven ground, crane boom, suspended load, construction, mech mat handling, struck by, work surface, crane, overturn
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Alteration or rehabilitation Under $50,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 300590676 Fatality Other Occupation not reported FallDist:
FallHt:
Cause: Excavation
FatCause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.