Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 83288.015 - Employee enters vessel and is killed.

Accident Summary Nr: 83288.015 -- Report ID: 0626600 -- Event Date: 02/24/2016
Inspection NrDate OpenedSICNAICSEstablishment Name
1128150.01502/24/2016541380Mechanical Testing Services, Llc

Abstract: At 6:00 a.m. on February 24, 2016, an employee was found unresponsive in the bottom of a testing vessel/containment box containing liquid nitrogen. The employee died.

Keywords: Asphyxiated, Confined Space, Oxygen Deficiency, Suffocated

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1128150.015 35 M Fatality Technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.