Accident Report Detail
Accident: 810168 - One Employee Dies, Four Others Injured By Hazordous Fumes
Accident: 810168 -- Report ID: 0453710 -- Event Date: 12/31/1989 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
18464008 | 01/01/1990 | 2257 | Wales Fabrics | ||||
On December 31, 1989, Employee #1 was repairing a small valve. He dropped a Teflon gasket through the grated floor below. A large liquid waste site was beneath the grate. At the time of incident, the site was dry. Employee #1 climbed down an access ladder to get into the pit. He traveled approximately 18 feet to the dropped gasket, collapsed, and died. Employees #2 through #5 tried to rescue the Employee #1. Employees #2 through #5 were taken to the hospital for observation and released. No other injuries occurred at the site. | |||||||
Keywords:
maintenance, asphyxiated, ppe, toxic atmosphere, grating, pit, chemical vapor
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 18464008 | Non Hospitalized injury | Asphyxia | Miscellaneous textile machine operators | |||
2 | 18464008 | Non Hospitalized injury | Other | Miscellaneous textile machine operators | |||
3 | 18464008 | Fatality | Asphyxia | Machinery maintenance occupations | |||
4 | 18464008 | Non Hospitalized injury | Other | Miscellaneous textile machine operators | |||
5 | 18464008 | Non Hospitalized injury | Other | Production samplers and weighers |