Accident Summary Nr: 800946 - Employee dies of burns after melter explodes
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 120479332 | 05/27/1993 | 2834 | 0 | General Nutrition Products (Gnp) |
Abstract: Employee #1 was cleaning melter #1. He had put 400 gallons of water and 5 kilos of trisodium phosphate into the melter. He sealed it to bring it to a boil. The manway blew off and the contents scalded Employee #1. Employee #1 sustained burns over his entire body and died. There was no safety relief device, alarm, or temperature gauge on this vessel.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120479332 | Fatality | Burn/Scald(Heat) | Mixing and blending machine operators |