Accident: 794511 - Employee Burned When Drum Containing Vapors Explodes

Accident: 794511 -- Report ID: 0253660 -- Event Date: 07/09/1990
InspectionOpen DateSICEstablishment Name
10492513607/09/19907999Chili Tn Offices & Highway Dept
Employee #1 was cutting the top off a drum that had contained methyl alcohol with an acetylene/oxygen torch. The drum exploded when the flame from the torch contacted the methanol vapors inside the drum. The employee was burned on the right side of his face, arm, and abdomen.
Keywords: burn, methyl alcohol, abdomen, acetylene torch, flammable vapors, work rules, drum, explosion, face, cutting and burning
Employee # Inspection Age Sex Degree Nature Occupation
1 104925136 Hospitalized injury Burn/Scald(Heat) Groundskeepers and gardeners, except farm

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.