Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 785048 - Employee's fingers amputated in punch press

Accident Summary Nr: 785048 -- Report ID: 1054112 -- Event Date: 05/25/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10518698505/25/198935990Harco Manufacturing Co

Abstract: At approximately 2:50 p.m. on May 17, 1989, Employee #1 was operating an L & J 50 ton punch press to form 1 1/8 in. by 34 in. long pieces with a press brake-type die set. To achieve the close tolerances required for these parts, Employee #1 had to lower the ram adjustment to get the worn shop-built dies to close adequately. After the ram of the press stopped at the top of its stroke on the 43rd part, Employee #1 reached into the dies with his right hand to retrieve the part. The clutch key broke and the ram came down on his hand. Employee #1 pulled his hand back as the dies opened and the machine continued to stroke. Portions of all four fingers on his right hand were amputated.

Keywords: DIE, AMPUTATED, INADEQUATE MAINT, PRESS BRAKE, FINGER, POINT OF OPERATION, PUNCH PRESS, RAM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105186985 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close