Accident Summary Nr: 781484 - Employees are overcome by xylene vapors, one hospitalized

Accident Summary Nr: 781484 -- Report ID: 0452110 -- Event Date: 05/09/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11234777805/09/199134650Ohi Automotive American Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
11235240605/10/199117520Kenway Distributors Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
11234777805/09/199134650Ohi Automotive American Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
11234776005/09/199115410James N Gray Construction Co

Abstract: Workers completing work on an expansion facility at an existing production site were applying a urethane coating to the facility's floor. Xylene vapors from the urethane coating migrated from the expansion facility to another building where Employees #1 through #10, production workers, began to experience symptoms typical of solvent exposure. Employee #1, who was suffering chest pains, was held overnight at a hospital for observation. Employees #2 through #10 were given oxygen therapy and released.

Keywords: RESPIRATORY, XYLENE, INHALATION, TOXIC FUMES, OVEREXPOSURE, CHEST, VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
2 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
3 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
4 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
5 112347778 Hospitalized injury Other Punching and stamping press machine operators
6 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
7 112352406 Occupation Not Listed
8 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
9 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
10 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
11 112347778 Non Hospitalized injury Other Punching and stamping press machine operators
12 112347760 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.