Accident Report Detail
Accident Summary Nr: 780510 - Employee crushed to death by falling heat exchanger
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 123782799 | 09/21/1994 | 1711 | 238220 | James E. Smith Mechanical Inc. |
Abstract: On September 19, 1994, employees were installing a 7,000 pound heat exchange unit. The unit became unbalanced, swung out of control, and fell onto Employee #1, crushing him against the wall. Employee #1 died.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123782799 | Fatality | Other | Supervisors; plumbers, pipefitters & steamfitters |
Translate