Accident: 743807 - Employee Killed By Falling Crane Boom In Trench

Accident: 743807 -- Report ID: 0951510 -- Event Date: 09/30/1991
InspectionOpen DateSICEstablishment Name
10388849110/01/19911541Pan Pacific Construction Inc Dba Ppc-Tokyu Joint V
At 2:55 p.m. on September 30, 1991, Employee #1 and a coworker were having a Rammax compactor lowered into an approximately 3 ft trench by a 35 ton P & H crawler crane #CR7, serial #J7057. The coworker was on the right side of the crane giving hand signals to the crane operator to lower the compactor into the trench. After lowering, he stood by while Employee #1 went into the trench to unhook the slings from the compactor. The boom hoist cable snapped and the boom fell to the ground, striking Employee #1 on the head and killing him.
Keywords: head, wire rope, crane boom, construction, equipment failure, struck by, falling object
Employee # Inspection Age Sex Degree Nature Occupation
1 103888491 Fatality Other Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.