Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 741314 - EMPLOYEE'S FINGER AMPUTATED IN SHEAR MACHINE

Accident Summary Nr: 741314 -- Report ID: 0950643 -- Event Date: 08/21/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11201916109/05/199134320Price Pfister, Inc.

Abstract: AT ABOUT 11:20 AM ON AUGUST 21, 1991, EMPLOYEE #1, A MACHINE OPERATOR, WAS OPERATING A PNEUMATIC POWERED, HORIZONTAL SHEAR TO CUT (SHORTEN) PLASTIC TUBES. THE 4.75-INCH-LONG BY 1.5-INCH-DIAMETER TUBES ARE USED AS SHIPPING PROTECTION FOR PLUMBING ITEMS. THE OPERATOR MANUALLY PLACES AND REMOVES THE TUBES. WHILE REMOVING A CUT TUBE FROM THE 1.5-INCH-DIAMETER STOCK OPENING, THE OPERATOR PUSHED ONE OF THE TWO MACHINE ACTIVATE BUTTONS AND THE SHEAR BLADE AMPUTATED A PORTION OF A FINGER. THE MACHINE WAS PROVIDED WITH TWO-HAND CONTROL BUTTONS, BUT ONE BUTTON WAS MADE INOPERATIVE BY THE OPERATOR TO SPEED PRODUCTION.

Keywords: AMPUTATED, SHEAR, FINGER, WORK RULES, EQUIPMENT OPERATOR, TWO-HAND CONTROL, POINT OF OPERATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112019161 Non Hospitalized injury Amputation Slicing and cutting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close