Accident Report Detail
Accident Summary Nr: 675405 - Two employees are injured when furnace explodes
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 120462585 | 03/03/1992 | 3341 | 0 | Gaston Copper Recycling |
Abstract: An explosion occurred at a converter furnace while employees were charging the furnace using a hervoist and a scoop loader. The explosion occurred when tank house sludge (wet material) was charged directly into the furnace. Employee #1 was injured from debris and dust that got into his eyes and from metal slag blown from the furnace due to the explosion. Employee #2 injured his back during the evacuation from the furnace. Employee #1 was acting as the operator and was not familiar with all the materials charged to the converter furnace. The regular furnace operator was not present as he was under medical surveillance. The tank house sludge was not checked for moisture content nor was it mixed with other materials to prevent the molten metal and moisture from mixing.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120462585 | Non Hospitalized injury | Foreign Body Ineye | Furnace, kiln and oven operators | ||
| 2 | 120462585 | Non Hospitalized injury | Strain/Sprain | Miscellaneous material moving equipment operators |