Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 6380.015 - Employee Strikes Head on Concrete Floor After Being Struck b

Accident Summary Nr: 6380.015 -- Report ID: 0523400 -- Event Date: 02/07/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
190976.01502/07/2012491110United States Postal Service

Abstract: At 7:30 p.m. on February 7, 2012, Employee #1 had just finished unloading a trailer and was standing between docks 10 and 11. A coworker, forklift operator, was pulling a load of empty letter trays from a trailer in dock 3. This coworker struck Employee #1 while backing up. Employee #1 was struck in the leg by the forklift and his leg became trapped. Employee #1 tried pulling his leg free but fell backwards, striking his head on the concrete floor.

Keywords: Concrete Slab, Dock, Fall, Head, Industrial Truck, Leg, Tractor Trailer

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 190976.015 1 M Hospitalized injury Postmasters and mail superintendents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.