Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 599811 - Employee Killed When Crushed Between Forklift And Truck

Accident: 599811 -- Report ID: 0418100 -- Event Date: 01/13/1993
InspectionOpen DateSICEstablishment Name
120130001/13/19935211Tucker Materials, Inc.
Employee #1 had arrived at about 4:00 a.m. and was the only one on site. He was using a forklift to load Sheetrock onto flatbed delivery trucks. After loading two trucks, he started to load the third truck. He stopped the lift in the yard on a slight slope, put it in neutral, and set the parking brake, which was inoperative due to a broken cable. Employee #1 did not lower the load. He was standing between the load and the flatbed truck, onto which he was placing dunnage for placement of the Sheetrock load. The forklift rolled forward and pinned him between the load of Sheetrock and the flatbed truck. At around 6:35 a.m., Employee #1 was found dead by coworkers.
Keywords: loading, vehicle in gear, brake, inadequate maint, pinned, work rules, equipment failure, industrial truck, flatbed truck, slope
Employee # Inspection Age Sex Degree Nature Occupation
1 1201300 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close