Accident Report Detail
Accident Summary Nr: 47446.015 - Employee is burned and receive electric shock through faulty
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
---|---|---|---|---|
913190.015 | 06/18/2013 | 333120 | Jlg Industries Inc. |
Abstract: At 3:00 a.m. on June 11, 2013, an employee was welding a C-collar to a tube using a Miller DC Mig Welder, operating at 330 Amp, 20-27 Volts. The employee received an electrical shock when the welding lead arced on the mid tube through a damaged area of insulation that had been repaired with electrical tape and grounded through the employees metal belt buckle that was touching the mid-tube. The employee was electrocuted, suffering paralysis from the elbow to his hand on the right arm and had electrical burns on their right shoulder, upper chest, and lower abdomen.
Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 913190.015 | 25 | M | Hospitalized injury | Welders and cutters |