Accident: 202674966 - Employee Sustains Chemical Burns From Nitric Acid Spray

Accident: 202674966 -- Report ID: 0950621 -- Event Date: 04/11/2013
InspectionOpen DateSICEstablishment Name
31651558404/18/20130181The Sun Valley Group Inc
On April 11, 2013, Employee #1, with the Sun Valley Group Inc., was transferring nitric acid from a drum to an irrigation tank, when concentrated nitric acid was sprayed on him from holes in improper tubing from the drum. Employee #1 was hospitalized for two days for treatment of second degree burns on multiple body parts. The employer received a serious, accident related citation for failing to maintain the piping/tubing in accordance with good engineering practice.
Keywords: maintenance, inadequate maint, drum, pressure piping, nitric acid, chemical
Employee # Inspection Age Sex Degree Nature Occupation
1 316515584 Hospitalized injury Burn(Chemical) Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.