Accident: 202658779 - Employee Suffers Leg Fracture When Struck By Metal Bundle

Accident: 202658779 -- Report ID: 0950643 -- Event Date: 11/04/2013
InspectionOpen DateSICEstablishment Name
31667206212/10/20135051Borrmann Metal Center
On November 4, 2013, Employee #1, a warehouse man with Borrmann Metal Center, and a coworker, were working in the B-Bay pit area and were stacking a bundle of metal flat bar hoisted from a crane. Employee #1 was positioning dunnage (padding in a shipping container) onto a stacked bundle of metal to lower a bundle that was hoisted by a crane. His coworker was positioning himself by climbing and standing on an adjacent set of stacked bundles. The dunnage twisted and broke, and the bundles rolled over and crushed Employee #1's right lower leg. The bundles that the coworker was standing on were not stacked properly. The stack was a set of three bundles. The bottom bundle was squared in shape, the middle bundle was circular in shape, and the top bundle was squared in shape. This adjacent stack of bundles rolled over and fell on Employee #1. The immediate supervisor was not in the area at the time of the accident. The factors that caused the accident were that the coworker climbed onto the stack of bundles and destabilized the stack that fell on Employee #1. Also, the stack of bundles was not properly stacked so as to make the pile stable. The square-shaped bundles should have been stacked at the bottom, and the circular-shaped bundle should have been placed on the top. Additionally, the dunnage that was used may not have been of adequate strength to support and stabilize the bundles. Employee #1 was hospitalized with a fractured lower right leg and a leg avulsion (the detachment of the leg bone fragment that was pulled away from its normal point of insertion, e.g., a ligament, tendon, or joint capsule).
Keywords: fracture, metal bar, stacker crane, warehouse, fall, struck by, dunnage, falling object, leg, unstable load
Employee # Inspection Age Sex Degree Nature Occupation
1 316672062 Hospitalized injury Other Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close